TR Bio Full
Electronic Lock with Random Password
• Dynamic Module with Bio and NFC
• Swingbolt or Deadbolt Lock
• NFC Cards
• Tora-dex TCP/IP Connectivity Board
• Stabilized Power Supply with Mini UPS

• Access via static passwords using ID, password, NFC, and biometrics;
• Up to 3 users with level 1 — administrative;
• Up to 10 users with level 2 — operational;
• Level 1 user managing users (register/delete/block/reactivate user/opening type);
• Static users with enrollment ID;
• Random user with closing code (embedding door/bolt open time);
• 6 opening modes;
• Dual combination possibility;
• Immediate locking by date/time or duration;
• Scheduled locking by date and time;
• Weekly scheduling;
• Automatic night lock (8:00 PM to 8:00 AM — configurable by level 1 user);
• Independent door and bolt sensors;
• Delay time: 00–99 min and window time: 00–19 min;
• Programmable door open alarm: 10–60 sec;
• Door interlock (can be enabled);
• Solenoid retraction time (6 sec / 12 sec / 18 sec);
• Language selection (Portuguese / English / Spanish);
• Configure number of locks (up to 9 smart locks);
• Penalty after 4 incorrect passwords with 30-minute timeout per user;
• Audit of the last 2,024 events;
• Remote functionalities via connectivity board (TCP/IP);

Connectivity Monitoring

• Change passwords of level 01 and 02 users;
• Add, delete, block, and unblock users and their opening types (level 01 and 02);
• Enable dual or single combination;
• Perform remote locking/unlocking of the lock;
• Set, change, and check delay and window times;
• Set, change, and check weekly schedule;
• Change and check night lock status on the lock;
• Set and check date and time of immediate locking;
• Set and check date and time of scheduled locking;
• Activate, synchronize code, and deactivate the lock’s random system;
• Change and check the lock’s opening mode (1, 2, 3, 4, 5, or 6);
• Audit the last 500 events of the lock;
• Change and check solenoid open time;
• Enable or disable door interlock;
• Delete the random system from the lock if active;
• Restore the lock to factory settings;

• Check if level 01 and 02 users still use factory default passwords;
• Check if level 01 and 02 users are enabled on the lock;
• Check the status and enrollment of level 01 and 02 users;
• Check the current date and time set on the lock;
• Check if the lock is in immediate locking mode;
• Check if the lock is in night lock mode;
• Check if the lock is enabled in the random system;
• Check if the lock is set to single or dual combination;
• Check if the door is open;
• Check if the bolts are open;
• Check if the lock is in delay or window mode;